Drain Line heaters
Drain pipe heaters are apt to be laid inside pipes for draining water from Refrigeration equipment, bottom of collector trays to prevent freezing and allow condensate water to flow freely. Drain Pipe Heating Cables are uniquely designed to be laid inside pipes for draining water from thawing refrigeration equipment installed in cold rooms. They operate only during thawing cycles. In cold stores, after a certain time of operation, there is a buildup of ice in cooler fins and defrosting must take place.
Description
Electric resistances are inserted between the fins to melt ice and water is collected and passed through a drain pipes for disposal. Some meters of drain pipes are inside the cold stores, so consequently the water may freeze again.
To avoid this problem, Drain Pipe Heating Cables is inserted in to the pipe. It is switched on only during the defrosting cycles.
Drain Pipe Heating Cables is available in predetermined lengths with cold tail – prefabricated & tested in a carefully controlled factory environment.
Features :-
Extremely flexible | Voltage 230 V as standard | Double insulation
Technical Specification :-
| Temperature Range | -50 Deg.C To 180 Deg .C |
| Heating Wire | Nickel- Chrome |
| Heating Element Insulation | Silicone Rubber |
| Cold Zone | 1 Mtr on Each side |
| Operating Voltage | 230 V |
| Wattage | Up to 45 W/M |
Rang :-
| Length | 1 | 2 | 3 | 4 | 5 | 6 |
| Wattage | 40 | 80 | 120 | 160 | 200 | 240 |
| Wattage | 50 | 100 | 150 | 200 | 250 | 300 |
Application :-
Cold storages | Refrigeration | Deep freeze